Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi C1146 — Konica-Minolta bizhub C3851FS

Code: C1146

Description: FD leading edge alignment motor malfunction <bizhub C3851FS> • The FD leading edge home sensor (FSPS1) is not turned OFF (unblocked) even after the lapse of a given period of time after the FD leading edge alignment motor (FSM1) is turned ON at start from the home position. • The FD leading edge alignment motor (FSM1) is not drive completion after the set period of time has elapsed even after the start of driving. • The FD leading edge home sensor (FSPS1) is not turned ON (blocked) even after the lapse of a given period of time after the FD leading edge alignment motor (FSM1) is turned ON at the initial operation.
Causes: • FD leading edge alignment motor (FSM1) • FD leading edge home sensor (FSPS1) • FS control board (FSCB)
Remedy: 1. Check the connector between FSM1-relay CN18-FSCB CN3 for proper connection and correct as necessary. 2. Check the connector of FSM1 for proper drive coupling, and correct as necessary. 3. Check the connector between FSPS1-FSCB CN5 for proper connection and correct as necessary. 4. FSPS1 I/O check, sensor check • Control signal: FSCB CN5-3 • Location of electrical component: 20-W 5. FSM1 operation check • Control signal: FSCB CN3-5 to 8 • Location of electrical component: 23-Q 6. Replace FSM1. 7. Replace FSCB.