Mã lỗi C1147 — Konica-Minolta bizhub C3851FS

Code: C1147

Description: FD trailing edge pushing motor malfunction <bizhub C3851FS> • The FD trailing edge home sensor (FSPS4) is not turned OFF (unblocked) even after the lapse of a given period of time after the FD trailing edge pushing motor (FSM4) is turned ON at start from the home position. • The FD trailing edge pushing motor (FSM4) is not drive completion after the set period of time has elapsed even after the start of driving. • The FD trailing edge home sensor (FSPS4) is not turned ON (blocked) even after the lapse of a given period of time after the FD trailing edge pushing motor (FSM4) is turned ON at the initial operation.
Causes: • FD trailing edge pushing motor (FSM4) • FD trailing edge home sensor (FSPS4) • FS control board (FSCB)
Remedy: 1. Check the connector between FSM4-relay CN20-FSCB CN3 for proper connection and correct as necessary. 2. Check the connector of FSM4 for proper drive coupling, and correct as necessary. 3. Check the connector between FSPS4-FSCB CN10 for proper connection and correct as necessary. 4. FSPS4 I/O check, sensor check • Control signal: FSCB CN10-10 • Location of electrical component: 24 to 25-Q 5. FSM4 operation check • Control signal: FSCB CN3-9 to 12 • Location of electrical component: 23-Q 6. Replace FSM4. 7. Replace FSCB.