Description: Toner suction fan motor malfunction The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
Causes: • Toner suction fan motor (FM3) • MFP board (MFPB)
Remedy: 1. Check the connectors between FM3-relay CN301-MFPB CN12E for proper connection, and correct as necessary. 2. Check the fan for possible overload and correct as necessary. 3. FM3 operation check • Control signal: MFPB CN12E-6 (LOCK) • Location of electrical component: 26-C 4. Replace FM3. (bizhub C3851/C3351 / bizhub C3851FS) 5. MFPB F2E conduction check 6. Replace MFPB.