Mã lỗi C3822 — Konica-Minolta bizhub C3851FS

Code: C3822

Description: Fusing abnormally low temperature (TEM2) The fusing temperature sensor/2 (TEM2) continues to detect a temperature lower than a predetermined one for a predetermined period of time after warm-up is complete.
Causes: • Fusing unit • C3822: Fusing temperature sensor/2 (TEM2) • C3825: Fusing temperature sensor/1 (TEM1: center) • C3826: Fusing temperature sensor/1 (TEM1: edge) • DC power supply (DCPS) • MFP board (MFPB)
Remedy: 1. Check the fusing unit for correct installation (whether it is secured in position). 2. Check the open/close operation of the upper right door. 3. Check the fusing unit-MFPB CN13E, DCPS CN2 for proper connection and correct or change as necessary. 4. Replace the fusing unit. 5. Replace MFPB. 6. DCPS F102 conduction check 7. Replace DCPS.