Code: C5360
Description: Clean unit fan's failure to turn (When CU-202 is installed) The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
Causes: • Exhaust fan/1 (FM1) • Exhaust fan/2 (FM2) • Exhaust fan/3 (FM3) • Clean unit drive board (CUDB) • MFP board (MFPB)
Remedy: 1. Check the connector between CUDB CN1-relay CN400-MFPB CN26E for proper connection and correct as necessary. 2. Check the connector between FM1-relay CN401-CUDB CN2 for proper connection and correct as necessary. 3. Check the connector between FM2-relay CN402-CUDB CN2 for proper connection and correct as necessary. 4. Check the connector between FM3-relay CN403-CUDB CN2 for proper connection and correct as necessary. 5. Check the fan for possible overload and correct as necessary. 6. FM1 operation check • Control signal: CUDB CN2-1 (REM), CUDB CN2-3 (LOCK) • Location of electrical component: 26-L 7. FM2 operation check • Control signal: CUDB CN2-4 (REM), CUDB CN2-6 (LOCK) • Location of electrical component: 27-L 8. FM3 operation check • Control signal: CUDB CN2-7 (REM), CUDB CN2-9 (LOCK) • Location of electrical component: 27-L 9. Replace the defective fan. (FM1 / FM2 / FM3) 10. Replace CUDB. 11. MFPB F11E conduction check 12. Replace MFPB.