Description: Side-staple front adjust drive motor malfunction <When FS-526 is installed> • The 2 staples alignment motor home sensor/F (PS17) is not turned ON even after the set period of time has elapsed while the Alignment plate motor/F (M11) is energized.
Causes: Alignment plate motor/F (M11) 2 staples alignment motor home sensor/F (PS17) FS control board (FSCB)
Remedy: 1 Check the motor and sensor connectors for proper connection, and correct as necessary. - - 2 Check the connector of M11 for proper drive coupling, and correct as necessary. - - 3 PS17 I/O check, sensor check FSCB CN20<A>-6 (ON) FS-526 L-11 4 M1 operation check FSCB CN19-1 to 4 FS-526 D-13 5 Change M1 - - 6 FSCB ICP4 conduction check - - 7 Change FSCB