Description: Center-staple clinch roller motor malfunction <When FS-526+SD-508 is installed> • The stapler home sensor (PS33) is not turned ON even after the set period of time has elapsed while the clincher motor (M25) is energized.
Causes: Clincher motor (M25) Stapler home sensor (PS33) SD drive board (SDDB) FS control board (FSCB)
Remedy: 1 Check the motor and sensor connectors for proper connection, and correct as necessary. - - 2 Check the connector of M25 for proper drive coupling, and correct as necessary. - - 3 PS33 I/O check, sensor check SDDB CN403-17 (ON) SD-508 C-10 4 M25 operation check SDDB CN405-4 to 10 SD-508 C-7 5 Change M25 - - 6 SDDB ICP6 conduction check - - 7 Change SDDB - - 8 Change FSCB