Mã lỗi C1115 — Konica-Minolta bizhub C452

Code: C1115

Description: Center-staple knife drive motor malfunction
<When FS-526+SD-508 is installed> • The center fold knife home sensor (PS34) is not turned ON even after the set period of time has elapsed while the center fold knife motor (M32) is energized. <When FS-527+SD-509 is installed> • The center fold plate home sensor (PS47) is turned neither ON nor OFF even after the set period of time has elapsed after the center fold plate motor (M26) is turned ON.
Causes: When FS-526+SD-508 is installed: Center fold knife motor (M32) Center fold knife home sensor (PS34) SD drive board (SDDB) FS control board (FSCB).
When FS-527+SD-509 is installed: Center fold plate motor (M26) Center fold plate home sensor (PS47) SD drive board (SDDB) FS control board (FSCB)
Remedy: When FS-526+SD-508 is installed: 1 Check the motor and sensor connectors for proper connection, and correct as necessary. - - 2 Check the connector of M32 for proper drive coupling, and correct as necessary. - - 3 PS34 I/O check, sensor check SDDB CN407-3 (ON) SD-508 K-6 4 M32 operation check SDDB CN411-1 to 2 SD-508 K-8 5 Change M32 - - 6 SDDB ICP8 conduction check - - 7 Change SDDB - - 8 Change FSCB.
When FS-527+SD-509 is installed: 1 Check the motor and sensor connectors for proper connection, and correct as necessary. - - 2 Check the connector of M26 for proper drive coupling, and correct as necessary. - - 3 PS47 I/O check, sensor check SDDB PJ10-6 (ON) SD-509 G-6 4 M26 operation check SDDB PJ2-1 (CW) SDDB PJ2-3 (CCW) SD-509 B-4 5 Change M26 - - 6 Change SDDB - - 7 Change F