Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi C1125 — Konica-Minolta bizhub C452

Code: C1125

Description: Sheet feeder up/down drive failure (upper)
<When FS-526+PI-505 is installed> • The tray lower limit sensor /Up (PS205) or tray upper limit sensor /Up (PS204) are not turned ON even after the set period of time has elapsed after the tray lift motor /Up (M201) is energized.
Causes: Tray lift motor /Up (M201) Tray upper limit sensor /Up (PS204) Tray lower limit sensor /Up (PS205) PI drive board (PIDB) FS control board (FSCB)
Remedy: 1 Check the motor and sensor connectors for proper connection, and correct as necessary. - - 2 Check the connector of M201 for proper drive coupling, and correct as necessary. - - 3 PS204 I/O check, sensor check PIDB CN55-8 (ON) PI-505 C to D-5 4 PS205 I/O check, sensor check PIDB CN55-7 (ON) PI-505 C to D-6 5 M201 operation check PIDB CN54-7 to 8 PI-505 C to D-4 6 Change M201 - - 7 PIDB ICP2 conduction check - - 8 Change PIDB - - 9 Change FSCB