Description: Punch motor drive malfunction <When FS-527+PK-517 is installed> •The punch home sensor/1 (PS100) is not turned ON even after the set period of time has elapsed while the punch motor/1 (M100) is energized.
Causes: Punch motor/1 (M100) Punch home sensor/1 (PS100) FS control board (FSCB)
Remedy: 1 Check the motor and sensor connectors for proper connection, and correct as necessary. - - 2 Check the connector of M100 for proper drive coupling, and correct as necessary. - - 3 PS100 I/O check, sensor check FSCB PJ19-8 (ON) FS-527 (PK-517) J-9 4 M100 operation check FSCB PJ19-1 (CW) FSCB PJ19-3 (CCW) FS-527 (PK-517) J-8 5 Change M100 - - 6 Change FSCB