Code: C3B05
Description: IH temperature sensor defect
• While the IH heater was on, IH temperature sensor was disconnected for more than the predetermined period of time. • While the IH heater was on, short circuit on IH temperature sensor continued for more than the predetermined period of time. • While the IH heater was on, temperature change occurred within the predetermined period of time with over the predetermined range, and they continued for more than the predetermined period of time. • While the IH heater was on, temperature around the heat radiator stayed high for over the predetermined period of time.
• While the IH heater was on, IH temperature sensor was disconnected for more than the predetermined period of time. • While the IH heater was on, short circuit on IH temperature sensor continued for more than the predetermined period of time. • While the IH heater was on, temperature change occurred within the predetermined period of time with over the predetermined range, and they continued for more than the predetermined period of time. • While the IH heater was on, temperature around the heat radiator stayed high for over the predetermined period of time.
Causes: IH coil unit IH power supply (IHPU) Relay drive board (REDB) Printer control board (PRCB)
Remedy: 1 Check the connection of the fusing unit. - - 2 Check the fusing unit, degaussing coil unit, IHPU, PRCB and REDB for proper connection and correct or change as necessary. - - 3 Change degaussing coil unit - - 4 Change IHPU - - 5 Change PRCB - - 6 Change REDB