Description: Exposure turning on the lamp abnormally detection • The average output value of the CCD sensor with the scanner at its standby position is a predetermined value or more at the end of a scan job.
Remedy: 1 Check the connection between the lamp harness and the inverter board, and correct if necessary. - - 2 Check the connection between REYB/ SCAN and the inverter board, and correct if necessary. - - 3 Check the connection between REYB/ SCAN and MFPB, and correct if necessary. - - 4 Check that the connection between CCDB and MFPB, and correct if necessary. - - 5 Change INVB - - 6 Change exposure unit - - 7 Change CCDB - - 8 Change REYB/SCAN - - 9 Change MFPB