Description: Tray 3 lift-up failure The tray 3 upper limit sensor (PS116) is not blocked even after the set period of time has elapsed after the paper lift-up operation for the drawer began.
Remedy: 1 Check the connector between M113-PCCB CN6 for proper connection and correct as necessary. 2 Check the connector of M113 for proper drive coupling and correct as necessary. 3 Check the connector between PS116-relay CN24- PCCB CN4 for proper connection and correct as necessary. 4 PS116 I/O check, sensor check PCCB CN4-3 (ON) PC-110/PC-210 7-C 5 M113 operation check PCCB CN6-8 to 9 PC-110/PC-210 2-C 6 Replace M113. 7 Replace PCCB. 8 Replace MFPB.