Mã lỗi C3B07 — Konica-Minolta bizhub C454

Code: C3B07

Description: IH input power error
• While the IH heater was ON, input power stayed at the high voltage power detection value or over for more than the predetermined period of time. • While the IH heater was ON, input power was at the low power detection value or under for more than the predetermined period of time. • While the IH heater was ON, input power was at the high voltage detection value or over for more than the predetermined period of time. • While the IH heater was ON, input power was below the low voltage detection value or under for more than the predetermined period of time. • While the IH heater was ON, inverter power stayed at the upper limit value or over for more than the predetermined period of time. • While the IH heater was ON, output voltage halt was detected.
Remedy: 1 Check the connection of the fusing unit. 2 Check the fusing unit, IHC, IHPU and PRCB for proper connection and correct or change as necessary. 3 Replace IHC. 4 Replace IHPU. 5 Replace PRCB.