Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi C6104 — Konica-Minolta bizhub C454

Code: C6104

Description: Back side cleaning home sensor abnormality (initial)
• The CIS cleaning sensor (PS7) does not change from H to L even after the lapse of a given period of time after the home position detecting operation is started at the initial operation. • The CIS cleaning sensor (PS7) does not change from L to H even after the lapse of a given period of time after the home position detecting operation is started at the initial operation.
Remedy: 1 Check if the opening and closing guide is firmly closed. 2 Check the connector between M5-DFCB J9 for proper connection, and correct as necessary. 3 Check the connector of M5 for proper drive coupling, and correct as necessary. 4 Check the connector between PS7-DFCB J13 for proper connection, and correct as necessary. 5 PS7 I/O check, sensor check DRCB J13-3 (ON) DF-701 1-G. 6 M5 operation check DRCB J9-1 to 4 DF-701 6-G. 7 Replace M5. 8 Replace DFCB.