Description: Tray 1 feeder up/down abnormality The tray 1 upper limit sensor (PS22) is not blocked even after the lapse of a given period of time after the lifting motion has been started.
Remedy: 1 Check the connector between M12-PRCB CN25 for proper connection and correct as necessary. 2 Check the connector of M12 for proper drive coupling and correct as necessary. 3 Check the connector between PS25-relay CN30- PRCB CN26 for proper connection and correct as necessary. 4 PS25 I/O check, sensor check PRCB CN26-3 (ON) 7-C. 5 M12 operation check PRCB CN25-5 (REM) 1-C. 6 Replace M12. 7 PRCB ICP5 conduction check. 8 Replace PRCB.