Description: Sheet feeder up/down drive failure (upper) <When FS-535+PI-505 is installed> The tray lower limit sensor /Up (PS205) or tray upper limit sensor /Up (PS204) are not turned ON even after the set period of time has elapsed after the tray lift motor /Up (M201) is energized.
Remedy: 1 Check the connector between M201-relay CN203- PIDB CN54 for proper connection, and correct as necessary. 2 Check the connector of M201 for proper drive coupling, and correct as necessary. 3 Check the connector between PS204-relay CN235- PIDB CN55 for proper connection, and correct as necessary. 4 Check the connector between PS205-relay CN235- PIDB CN55 for proper connection, and correct as necessary. 5 PS204 I/O check, sensor check PIDB CN55-8 (ON) PI-505 5-C to D. 6 PS205 I/O check, sensor check PIDB CN55-7 (ON) PI-505 6-C to D. 7 M201 operation check PIDB CN54-7 to 8 PI-505 4-C to D. 8 Replace M201. 9 PIDB ICP2 conduction check. 10 Replace PIDB. 11 Replace FSCB.