Mã lỗi C3101, C3103 — Konica-Minolta bizhub C458

Code: C3101, C3103

Description: • C3101: Pressure roller pressure failure • C3103: Pressure roller release failure. C3101: • The encoder pulse does not change even after the lapse of a predetermined period of time after the fusing pressure motor (M11) has started rotating during pressure by the pressure roller. • The fusing pressure home sensor (PS38) is not blocked even after the lapse of a predetermined period of time after the fusing pressure motor (M11) has started rotating during pressure by the pressure roller. C3103: • The encoder pulse does not change even after the lapse of a predetermined period of time after the fusing pressure motor (M11) has started rotating during retraction of the pressure roller. • The fusing pressure home sensor (PS38) is not unblocked even after the lapse of a predetermined period of time after the fusing pressure motor (M11) has started rotating during retraction of the pressure roller.
Causes: • Fusing unit • Fusing pressure motor (M11) • Fusing pressure home sensor (PS38) • MFP board (MFPB)
Remedy: 1. Check the connector between M11-MFPB CN15EA for proper connection and correct as necessary. 2. Check the connector between the fusing unit-relay CN98, CN99, CN104-MFPB CN13E for proper connection and correct as necessary. 3. PS38 I/O check, sensor check • Control signal: MFPB CN13E-12 (ON) • Location of electrical component: 11-C 4. M11 operation check • Control signal: MFPB CN15EA-5 to 8 • Location of electrical component: 6-C 5. Replace M11. 6. Replace the fusing unit. 7. Replace MFPB.

← Xem tất cả mã lỗi Konica-Minolta bizhub C458

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie