Description: Before reading pressure welding alienation mechanism (When DF-629 or DF-704 is installed).<When DF-629 is installed> • During a pressure motion being performed, the document reading sensor (PS4) output does not change from H to L. • During a retraction motion being performed, the document reading sensor (PS4) output does not change from L to H. <When DF-704 is installed> • During a pressure motion being performed, the document reading sensor (PS6) output does not change from H to L. • During a retraction motion being performed, the document reading sensor (PS6) output does not change from L to H.
Causes: <When DF-629 is installed> • Reading roll release motor (M5) • Document reading sensor (PS4) • DF control board (DFCB) <When DF-704 is installed> • Reading roller release motor (M4) • Document reading sensor (PS6) • DF control board (DFCB)
Remedy: When DF-629 is installed 1. Check the connector between M5-DFCB J18 for proper connection and correct as necessary. 2. Check the connector of M5 for proper drive coupling and correct as necessary. 3. Check the connector between PS4-DFCB J10 for proper connection and correct as necessary. 4. PS4 I/O check, sensor check • Control signal: DFCB J10-3 (ON) • Location of electrical component: DF-629 2-G 5. M5 operation check • Control signal: DFCB J18-4 to 5 • Location of electrical component: DF-629 2-G 6. Replace M5. 7. Replace DFCB. When DF-704 is installed 1. Check the connector between M4-DFCB J18 for proper connection and correct as necessary. 2. Check the connector of M4 for proper drive coupling and correct as necessary. 3. Check the connector between PS6-DFCB J10 for proper connection and correct as necessary. 4. PS6 I/O check, sensor check • Control signal: DFCB J10-3 (ON) • Location of electrical component: DF-704 2-G 5. M4 operation check • Control signal: DFCB J18-4 to 5 • Location of electrical component: DF-704 1-G 6. Replace M4. 7. Replace DFCB.