Description: Cooling fan trouble (When DF-629 or DF-704 is installed). <When DF-629 is installed> • The lock signal continues to detect H during a given time while the DF cooling fan motor (FM1) is spinning. • The lock signal continues to detect L during a given time while the DF cooling fan motor (FM1) is during halts. <When DF-704 is installed> • The lock signal continues to detect H during a given time while the DF cooling fan motor (FM1) is spinning. • The lock signal continues to detect L during a given time while the DF cooling fan motor (FM1) is during halts.
Causes: <When DF-629 is installed> • DF cooling fan motor (FM1) • DF control board (DFCB) <When DF-704 is installed> • DF cooling fan motor (FM1) • DF control board (DFCB)
Remedy: When DF-629 is installed 1. Check the connector between FM1-DFCB J16 for proper connection and correct as necessary. 2. Check the fan for possible overload and correct as necessary. 3. FM1 operation check • Control signal: DFCB J16-3 (ON) • Location of electrical component: DF-629 3-B 4. Replace FM1. 5. Replace DFCB. When DF-704 is installed 1. Check the connector between FM1-DFCB J16 for proper connection and correct as necessary. 2. Check the fan for possible overload and correct as necessary. 3. FM1 operation check • Control signal: DFCB J16-3 (ON) • Location of electrical component: DF-704 7-G 4. Replace FM1. 5. Replace DFCB.