Code: C6103
Description: Slider over running
• The scanner home sensor detects the scanner at its home position during a period of time that begins with the time when a prescan command and a scan preparation command are executed and ends when a home return command is executed.
• The scanner home sensor detects the scanner at its home position during a period of time that begins with the time when a prescan command and a scan preparation command are executed and ends when a home return command is executed.
Remedy: 1 Correct or change the scanner drive (cable, pulley, gear, belt) if it is faulty. 2 Correct the scanner motor set screw if loose. 3 Adjust [Image Position Leading Edge] and [Feed Direction Adjustment]. 4 Check the PS201, M201, REYB/SCAN and IPB connector for proper connection and correct as necessary. 5 PS201 I/O check, sensor check IPB CN11IPB-3 (ON) T-15 6 M201 operation check REYB/SCAN CN5REYB/SCAN-4 to 7 Q to R-18. 7 Change REYB/SCAN. 8 Change IPB.