Description: 2nd stopper motor drive malfunction <When FS-526+ZU-606 is installed> • The 2nd stopper home sensor (PS604) is not turned ON even after the set period of time has elapsed after the 2nd stopper motor (M603) starts searching home position.
Causes: 2nd folding stopper motor (M603) 2nd folding stopper home sensor (PS604) ZU control board (ZUCB)
Remedy: 1 Check the motor and sensor connectors for proper connection, and correct as necessary. - - 2 Check the connector of M603 for proper drive coupling, and correct as necessary. - - 3 PS604 I/O check, sensor check ZUCB CN4-5 (ON) ZU-606 C-4 to 5 4 M603 operation check ZUCB CN15-7 to 12 ZU-606 C-4 5 Change M603 - - 6 ZUCB ICP6 conduction check - - 7 Change ZUCB