Mã lỗi C3425 — Konica-Minolta bizhub C552

Code: C3425

Description: Fusing heaters trouble (NC sensor)
• After warm-up operation starts, the heating roller temperature sensor/1 does not detect a temperature as high as a predetermined one though a predetermined period of time has elapsed.
Causes: Fusing unit Heating roller temperature sensor/1 (TEMS1) IH power supply (IHPU) Relay drive board (REDB) Printer control board (PRCB)
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). - - 2 Check the open/close operation of the upper right door. - - 3 Check the fusing unit, IHPU, MFPB and REDB for proper connection and correct or change as necessary. - - 4 Change TEMS1 - - 5 Change fusing unit - - 6 Change IHPU - - 7 PRCB ICP17 conduction check - - 8 Change PRCB - - 9 Change REDB