Description: PH cooling fan motor failure to turn • The fan motor lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary.
Causes: PH cooling fan motor (FM14) PH relay board (REYB/PH) Printer control board (PRCB)
Remedy: 1 Check the FM14 connector for proper connection and correct as necessary. - - 2 Check the fan for possible overload and correct as necessary. - - 3 FM14 operation check REYB/PH CN4-1 (REM) REYB/PH CN4-3 (LOCK) A to B-7 4 Change FM14 - - 5 REYB/PH ICP1 conduction check - - 6 Change REYB/PH - - 7 Change DCPU