Description: Before reading pressure welding alienation mechanism •During a pressure motion being performed, the read roller sensor (PS6) output does not change from H to L. •During a retraction motion being performed, the read roller sensor (PS6) output does not change from L to H.
Causes: Reading roller pressure/retraction motor (M4) Read roller sensor (PS6) DF control board (DFCB)
Remedy: 1 Check the motor and sensor connectors for proper connection, and correct as necessary. - - 2 Check the connector of M4 for proper drive coupling, and correct as necessary. - - 3 PS6 I/O check, sensor check DFCB PJ6-3 (ON) DF-618 I-4 4 M4 operation check DFCB PJ6-5 to 6 DF-618 I-4 5 Change M4 - - 6 DFCB PS3 conduction check - - 7 Change DFCB