Description: Turn around pressure welding alienation trouble •During a pressure motion being performed, the reverse roller sensor (PS7) output does not change from H to L. •During a retraction motion being performed, the reverse roller sensor (PS7) output does not change from L to H.
Causes: Switchback roller pressure/retraction motor (M5) Reverse roller sensor (PS7) DF control board (DFCB)
Remedy: 1 Check the motor and sensor connectors for proper connection, and correct as necessary. - - 2 Check the connector of M5 for proper drive coupling, and correct as necessary. - - 3 PS7 I/O check, sensor check REYB PJ3-3 (ON) DF-618 K to L-10 4 DFCB F9 conduction check - - 5 M5 operation check DFCB PJ6-10 to 11 DF-618 I-7 6 Change M5 - - 7 DFCB PS2 conduction check - - 8 Change DFCB