Description: Lift up mechanism trouble (Upward movement) • The lift up upper sensor (PS16) is not turned ON after a lapse of a given time after the lift-up motor (M6) moves up (is turned forward).
Causes: Lift-up motor (M6) Lift-up upper sensor (PS16) DF control board (DFCB)
Remedy: 1 Check the motor and sensor connectors for proper connection, and correct as necessary. - - 2 Check the connector of M6 for proper drive coupling, and correct as necessary. - - 3 PS16 I/O check, sensor check DFCB PJ11-3 (ON) DF-618 B-6 4 M6 operation check DFCB PJ5-6 to 7 DF-618 I-7 to 8 5 Change M6 - - 6 Change DFCB