Mã lỗi C8302 — Konica-Minolta bizhub C552

Code: C8302

Description: Cooling fan failure
• While the motor is running, the fan lock signal remains HIGH three times for a predetermined period of consecutive time.
Causes: DF-618: Cooling fan (FM1) DF control board (DFCB).
DF-619: Take-up cooling fan motor (FM1) DF control board (DFCB)
Remedy: DF-618: 1 Check the connector of FM1 for proper connection and correct as necessary. - - 2 Check the fan for possible overload and correct as necessary. - - 3 FM1 operation check DFCB PJ7-1 to 3 DF-618 I-2 to 3 4 Change FM1 - - 5 DFCB F7 conduction check - - 6 Change DF.
DF-619: 1 Check the connector of FM1 for proper connection and correct as necessary. - - 2 Check the fan for possible overload and correct as necessary. - - 3 FM1 operation check DFCB PJ13-1 to 3 DF-619 C-4 4 Change FM1 - - 5 DFCB ICP5 conduction check - - 6 Change DFCB