Mã lỗi C1124 — Konica-Minolta bizhub C552DS

Code: C1124

Description: Sheet feeder up/down drive failure (lower)
<When FS-526+PI-505 is installed> • The tray upper limit sensor /Lw (PS209) or tray lower limit sensor /Lw (PS210) are not turned ON even after the set period of time has elapsed after the tray lift motor /Lw (M202) is energized.
Causes: Tray lift motor /Lw (M202) Tray upper limit sensor /Lw (PS209) Tray lower limit sensor /Lw (PS210) PI drive board (PIDB) FS control board (FSCB)
Remedy: 1 Check the motor and sensor connectors for proper connection, and correct as necessary. - - 2 Check the connector of M202 for proper drive coupling, and correct as necessary. - - 3 PS209 I/O check, sensor check PIDB CN53<A>-8 (ON) PI-505 C to D-8 4 PS210 I/O check, sensor check PIDB CN53<A>-11 (ON) PI-505 C to D-9 5 M202 operation check PIDB CN56-5 to 6 PI-505 C to D-7 6 Change M202 - - 7 PIDB ICP2 conduction check - - 8 Change PIDB - - 9 Change FSCB