Mã lỗi C3721 — Konica-Minolta bizhub C552DS

Code: C3721

Description: Fusing abnormally high temperature detection (Center of the heating roller)
• The heating roller temperature sensor/2 continues to detect a temperature higher than a predetermined one for a predetermined period of time. • The signal is turned ON to activate the hard ratchet in the middle of the heating side.
Causes: Fusing unit Heating roller temperature sensor/1 (TEMS1) Heating roller temperature sensor/2 (TEMS2) Heating roller temperature sensor/3 (TEMS3) IH power supply (IHPU) Relay drive board (REDB) Printer control board (PRCB)
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). - - 2 Check the open/close operation of the upper right door. - - 3 Check the fusing unit, IHPU, MFPB and REDB for proper connection and correct or change as necessary. - - 4 Change TEMS1, TEMS2 or TEMS3 - - 5 Change fusing unit - - 6 Change IHPU - - 7 Change PRCB - - 8 Change REDB