Code: C392A
Description: Fusing sensor contamination (NC sensor)
• While checking the contamination on the heating roller temperature sensor/1, detected temperature of the heating roller thermistor/1 exceeded the detected temperature of the heating roller temperature sensor/1 for over the predetermined value for the predetermined period of time.
• While checking the contamination on the heating roller temperature sensor/1, detected temperature of the heating roller thermistor/1 exceeded the detected temperature of the heating roller temperature sensor/1 for over the predetermined value for the predetermined period of time.
Causes: Fusing unit Heating roller temperature sensor/1 (TEMS1) IH power supply (IHPU) DC power supply (DCPU) Printer control board (PRCB)
Remedy: 1 Wipe the TEMS1 clean of dirt if any. <Cleaning procedure> • Clear away a dirt or a foreign object on the sensor with a cotton swab. • When a dirt is left even if you cleaned the sensor by above procedure, clear away a dirt or a foreign object on the sensor using a cotton swab dampened with the alcohol. And, wipe off the sensor with a dry cotton swab afterwards. - - 2 Check the TEMS1 for installed position and proper connector connection. - - 3 Check the connection of the fusing unit. - - 4 Check the fusing unit, IHPU, PRCB and DCPU for proper connection and correct or change as necessary. - - 5 Change TEMS1 - - 6 Change fusing unit - - 7 PRCB ICP17 conduction check - - 8 Change PRCB