Description: Lift up mechanism failure (Downward movement) • The lift up lower sensor (PS15) is not turned ON after a lapse of a given time after the lift-up motor (M6) goes down (is turned backward).
Causes: Lift-up motor (M6) Lift-up lower sensor (PS15) DF control board (DFCB)
Remedy: 1 Check the motor and sensor connectors for proper connection, and correct as necessary. - - 2 Check the connector of M6 for proper drive coupling, and correct as necessary. - - 3 PS15 I/O check, sensor check REYB PJ3-6 (ON) DF-618 K to L-10 4 DFCB F9 conduction check - - 5 M6 operation check DFCB PJ5-6 to 7 DF-618 I-7 to 8 6 Change M6 - - 7 DFCB PS1 conduction check - - 8 Change DFCB