Code: C3101
Description: Fusing roller separation failure
• With the fusing roller being retracted, the fusing pressure home sensor (PS38) is not unblocked even after the specified period of time has passed after the fusing pressure motor (M11) started rotating. • With the fusing roller being pressed, the fusing pressure home sensor (PS38) is not blocked even after the specified period of time has passed after the fusing pressure motor (M11) started rotating.
• With the fusing roller being retracted, the fusing pressure home sensor (PS38) is not unblocked even after the specified period of time has passed after the fusing pressure motor (M11) started rotating. • With the fusing roller being pressed, the fusing pressure home sensor (PS38) is not blocked even after the specified period of time has passed after the fusing pressure motor (M11) started rotating.
Remedy: 1 Check the connector between M11-relay CN112- PRCB CN13 for proper connection and correct as necessary. 2 Check the connector between fusing unit-relay CN95, CN96-PRCB CN4 for proper connection and correct as necessary. (bizhub C554). Check the connector between fusing unit-relay CN98, CN99, CN104-PRCB CN5 for proper connection and correct as necessary. (bizhub C454) 3 PS38 I/O check, sensor check PRCB CN4-9 (ON) (bizhub C554) PRCB CN5-12 (ON) (bizhub C454) - 4 M11 operation check PRCB CN13-1 to 4 bizhub C554 26-C bizhub C454 24-C. 5 Replace M11. 6 Replace the fusing unit (bizhub C554/bizhub C454). 7 PRCB IC26 conduction check. 8 Replace PRCB.