Description: Fusing abnormally high temperature detection (Main of the heating side) • Detected temperature of the heating roller temperature sensor (TEMS) goes beyond a given temperature for a given period of time consecutively. • The hard protector signal error is detected for a given period of time consecutively.d
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the open/close operation of the right door. 3 Check the fusing unit, IHPU (bizhub C554 only) and PRCB for proper connection and correct or change as necessary. 4 Replace the fusing unit (bizhub C554/bizhub C454). 5 Replace IHPU (bizhub C554 only). 6 Replace PRCB.