Mã lỗi C1140 — Konica-Minolta bizhub C558

Code: C1140

Description: Alignment plate motor/Rr malfunction (When FS-533, FS-534 or FS-534SD is installed) <When FS-533 is installed> • The alignment plate home sensor/R (PS109) is not turned OFF (unblocked) after the set period of time has elapsed after the plate drive starts from the home position. • The alignment plate home sensor/R (PS109) is not turned ON (blocked) after the set period of time has elapsed while the alignment motor/R (M106) is energized when the plate returns to the home position. <When FS-534 or FS-534SD is installed> • The alignment plate/R home sensor (PS13) is not turned ON (blocked) or OFF (unblocked) even after the set period of time has elapsed while the alignment motor/Rear (M8) is energized.
Causes: <When FS-533 is installed> • Alignment motor/R (M106) • Alignment plate home sensor/R (PS109) • FS control board (FSCB) <When FS-534 or FS-534SD is installed> • Alignment motor/Rear (M8) • Alignment plate/R home sensor (PS13) • FS control board (FSCB)
Remedy: When FS-533 is installed 1. Check the connector between M106-FSCB CN102 for proper connection and correct as necessary. 2. Check the connector of M106 for proper drive coupling and correct as necessary. 3. Check the connector between PS109-FSCB CN102 for proper connection and correct as necessary. 4. PS109 I/O check, sensor check • Control signal: FSCB CN102 • Location of electrical component: FS-533 7-J 5. M106 operation check • Control signal: FSCB CN102 • Location of electrical component: FS-533 8-J 6. Replace M106 7. FSCB CP105 conduction check 8. Replace FSCB When FS-534 or FS-534SD is installed 1. Check the connector between M8-FSCB J12 for proper connection and correct as necessary. 2. Check the connector of M8 for proper drive coupling and correct as necessary. 3. Check the connector between PS13-FSCB J9 for proper connection and correct as necessary. 4. PS13 I/O check, sensor check • Control signal: FSCB J9<B>-9 (ON) • Location of electrical component: FS-534 9-C 5. M8 operation check • Control signal: FSCB J12-13 to 16 • Location of electrical component: FS-534 5 to 6-C to D 6. Replace M8. 7. Replace FSCB.

← Xem tất cả mã lỗi Konica-Minolta bizhub C558

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie