Description: • C3922: Fusing sensor wire breaks detection (Edge of the heating roller) • C3925: Fusing sensor wire breaks detection (Main of the heating roller) • C3926: Fusing sensor wire breaks detection (Center of the heating roller). • C3922: After a predetermined period of time after the warm-up stage is started, the heating roller thermistor/1 (TH1) voltage does not decrease by predetermined steps (temperature rise) within a predetermined period of time. • C3925: After a predetermined period of time after the warm-up stage is started, the heating roller temperature sensor (TEMS) voltage does not increase by predetermined steps (temperature rise) within a predetermined period of time. • C3926: After a predetermined period of time after the warm-up stage is started, the heating roller thermistor/2 (TH2) voltage does not decrease by predetermined steps (temperature rise) within a predetermined period of time.
Remedy: 1. Check the fusing unit for correct installation (whether it is secured in position). 2. Check the open/close operation of the right door. 3. Check the fusing unit and MFPB for proper connection and correct or change as necessary. 4. Replace the fusing unit. 5. Replace MFPB.