Description: • C6104: Back side cleaning home sensor abnormality (initial) (When DF-704 is installed) • C6105: Back side cleaning home sensor abnormality (normal) (When DF-704 is installed). C6104: • The CIS cleaning sensor (PS7) does not change from H to L even after the lapse of a given period of time after the home position detecting operation is started at the initial operation. • The CIS cleaning sensor (PS7) does not change from L to H even after the lapse of a given period of time after the home position detecting operation is started at the initial operation. C6105: At the time of operation other than the initial operation, the CIS cleaning sensor (PS7) error is detected.
Causes: • CIS cleaning sensor (PS7) • CIS cleaning motor (M5) • DF control board (DFCB)
Remedy: 1. Check if the opening and closing guide is firmly closed. 2. Check the connector between M5-DFCB J9 for proper connection and correct as necessary. 3. Check the connector of M5 for proper drive coupling and correct as necessary. 4. Check the connector between PS7-DFCB J13 for proper connection and correct as necessary. 5. PS7 I/O check, sensor check • Control signal: DFCB J13-3 (ON) • Location of electrical component: DF-704 1-G 6. M5 operation check • Control signal: DFCB J9-1 to 4 • Location of electrical component: DF-704 6-G 7. Replace M5. 8. Replace DFCB.