Description: Glass cleaning mechanism trouble (When DF-629 or DF-704 is installed). <When DF-629 is installed> The document reading glass cleaning sensor (PS12) is not turned ON after the set period of time has elapsed after the glass cleaning motor (M4) is turned ON. <When DF-704 is installed> The document reading glass cleaning sensor (PS13) is not turned ON after the set period of time has elapsed after the document reading glass cleaning motor (M6) is turned ON.
Causes: <When DF-629 is installed> • Glass cleaning motor (M4) • Document reading glass cleaning sensor (PS12) • DF control board (DFCB) <When DF-704 is installed> • Document reading glass cleaning motor (M6) • Document reading glass cleaning sensor (PS13) • DF control board (DFCB)
Remedy: When DF-629 is installed 1. Check the connector between M4-DFCB J8 for proper connection and correct as necessary. 2. Check the connector of M4 for proper drive coupling and correct as necessary. 3. Check the connector between PS12-DFCB J15 for proper connection and correct as necessary. 4. PS12 I/O check, sensor check • Control signal: DFCB J15-5 (ON) • Location of electrical component: DF-629 3-G 5. M4 operation check • Control signal: DFCB J8-1 to 4 • Location of electrical component: DF-629 1 to 2-B 6. Replace M4. 7. Replace DFCB. When DF-704 is installed 1. Check the connector between M6-DFCB J8 for proper connection and correct as necessary. 2. Check the connector of M6 for proper drive coupling and correct as necessary. 3. Check the connector between PS13-DFCB J15 for proper connection and correct as necessary. 4. PS13 I/O check, sensor check • Control signal: DFCB J15-5 (ON) • Location of electrical component: DF-704 3-G 5. M6 operation check • Control signal: DFCB J8-1 to 4 • Location of electrical component: DF-704 1-B 6. Replace M6. 7. Replace DFCB.