Code: C2557
Description: Abnormally low toner density detected black TCR sensor
• When sampling data is determined in TC ratio calculation control, TCR sensor output is higher than a predetermined value for a predetermined number of times in a row even though there is toner in the sub hopper.
• When sampling data is determined in TC ratio calculation control, TCR sensor output is higher than a predetermined value for a predetermined number of times in a row even though there is toner in the sub hopper.
Remedy: 1 Perform image troubleshooting procedure if image density is low. 2 Clean the TCR sensor window on the underside of the imaging unit if dirty 3 M12 operation check (At this time, IU must be non-installation.) PRCB CN16PRCB-13 to 16 C-22 4 M14 operation check PRCB CN17PRCB-9 to 12 K-1. 5 Reinstall imaging unit. 6 Reinstall toner cartridge. 7 If the toner empty sensor and its surroundings inside the sub hopper are dirtied with toner, clean them. 8 Change imaging unit /K. 9 Change PRCB.