Code: C1114
Description: Center-staple front adjust drive motor malfunction
<When FS-526+SD-508 is installed> • The center staple alignment motor home sensor/F (PS30) is turned neither ON nor OFF even after the set period of time has elapsed after the center staple alignment motor /F (M20) is turned ON. <When FS-527+SD-509 is installed> • The center staple alignment home sensor/F (PS42) is turned neither ON nor OFF even after the set period of time has elapsed after the center staple alignment motor/F (M24) is turned ON.
<When FS-526+SD-508 is installed> • The center staple alignment motor home sensor/F (PS30) is turned neither ON nor OFF even after the set period of time has elapsed after the center staple alignment motor /F (M20) is turned ON. <When FS-527+SD-509 is installed> • The center staple alignment home sensor/F (PS42) is turned neither ON nor OFF even after the set period of time has elapsed after the center staple alignment motor/F (M24) is turned ON.
Causes: When FS-526+SD-508 is installed: Center staple alignment motor /F (M20) Center staple alignment motor home sensor/F (PS30) SD drive board (SDDB) FS control board (FSCB).
When FS-527+SD-509 is installed: Center staple alignment motor/F (M24) Center staple alignment home sensor/F (PS42) SD drive board (SDDB) FS control board (FSCB)
When FS-527+SD-509 is installed: Center staple alignment motor/F (M24) Center staple alignment home sensor/F (PS42) SD drive board (SDDB) FS control board (FSCB)
Remedy: When FS-526+SD-508 is installed: 1 Check the motor and sensor connectors for proper connection, and correct as necessary. - - 2 Check the connector of M20 for proper drive coupling, and correct as necessary. - - 3 PS30 I/O check, sensor check SDDB CN403-14 (ON) SD-508 C-9 4 M20 operation check SDDB CN403-1 to 4 SD-508 C-8 5 Change M20 - - 6 SDDB ICP4 conduction check - - 7 Change SDDB - - 8 Change FSCB.
When FS-527+SD-509 is installed: 1 Check the motor and sensor connectors for proper connection, and correct as necessary. - - 2 Check the connector of M24 for proper drive coupling, and correct as necessary. - - 3 PS42 I/O check, sensor check SDDB PJ9-6 (ON) SD-509 G-2 4 M24 operation check SDDB PK7-1 to 4 SD-509 G-3 5 Change M24 - - 6 Change SDDB - - 7 Change FSCB
When FS-527+SD-509 is installed: 1 Check the motor and sensor connectors for proper connection, and correct as necessary. - - 2 Check the connector of M24 for proper drive coupling, and correct as necessary. - - 3 PS42 I/O check, sensor check SDDB PJ9-6 (ON) SD-509 G-2 4 M24 operation check SDDB PK7-1 to 4 SD-509 G-3 5 Change M24 - - 6 Change SDDB - - 7 Change FSCB