Description: Spare stacker board drive motor malfunction <When FS-526 is installed> • The stacker plate home sensor (PS11) is turned neither ON nor OFF even after the set period of time has elapsed while the stacker plate motor (M17) is energized.
Causes: Stacker plate motor (M17) Stacker plate home sensor (PS11) FS control board (FSCB)
Remedy: 1 Check the motor and sensor connectors for proper connection, and correct as necessary. - - 2 Check the connector of M17 for proper drive coupling, and correct as necessary. - - 3 PS11 I/O check, sensor check FSCB CN20<A>-12 (ON) FS-526 L-12 4 M17 operation check FSCB CN18-1 to 2 FS-526 D-12 5 Change M17 - - 6 FSCB ICP9 conduction check - - 7 Change FSCB