Description: Fusing cooling fan motor/ 2 failure to turn • The fan motor lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary.
Causes: Fusing cooling fan motor/2 (FM4) Paper feed/transport drive board (PFTDB)