Description: Fusing sensor wire breaks detection (Edge of the heating roller) • At the warm-up stage, the heating roller temperature sensor/3 voltage does not decrease by predetermined steps (temperature rise) within a predetermined period of time.
Causes: Fusing unit Heating roller temperature sensor/1 (TEMS1) Heating roller temperature sensor/2 (TEMS2) Heating roller temperature sensor/3 (TEMS3) IH power supply (IHPU) Relay drive board (REDB) Printer control board (PRCB)
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). - - 2 Check the open/close operation of the upper right door. - - 3 Check the fusing unit, IHPU, PRCB and REDB for proper connection and correct or change as necessary. - - 4 Change TEMS1, TEMS2 or TEMS3 - - 5 Change fusing unit - - 6 Change IHPU - - 7 PRCB ICP17 conduction check - - 8 Change PRCB - - 9 Change REDB