Code: C1182
Description: Shift motor drive malfunction
<When JS-504 is installed> • The shift home sensor (PS6) is not blocked after the set period of time has elapsed after the shift motor (M2) is turned ON (start of moving to the home position.) • The shift home sensor (PS6) is not unblocked twice in a row after the set period of time has elapsed after the shift motor (M2) is turned ON (start of moving to the shift position.) <When FS-527 is installed> • When moving to the front (home) position: The tray 1 shift home sensor (PS25) is not turned ON even after the set period of time has elapsed after the tray 1 shift motor (M16) is turned ON. • When moving to the rear (shift) position: The tray 1 shift home sensor (PS25) is not turned OFF even after the set period of time has elapsed after the tray 1 shift motor (M16) is turned ON.
<When JS-504 is installed> • The shift home sensor (PS6) is not blocked after the set period of time has elapsed after the shift motor (M2) is turned ON (start of moving to the home position.) • The shift home sensor (PS6) is not unblocked twice in a row after the set period of time has elapsed after the shift motor (M2) is turned ON (start of moving to the shift position.) <When FS-527 is installed> • When moving to the front (home) position: The tray 1 shift home sensor (PS25) is not turned ON even after the set period of time has elapsed after the tray 1 shift motor (M16) is turned ON. • When moving to the rear (shift) position: The tray 1 shift home sensor (PS25) is not turned OFF even after the set period of time has elapsed after the tray 1 shift motor (M16) is turned ON.
Causes: When JS-504 is installed: Shift motor (M2) Shift home sensor (PS6) JS control board (JSCB).
When FS-527 is installed: Tray2 shift motor (M16) Tray2 shift home sensor (PS25) FS control board (FSCB)
When FS-527 is installed: Tray2 shift motor (M16) Tray2 shift home sensor (PS25) FS control board (FSCB)
Remedy: When JS-504 is installed: 1 Check the motor and sensor connectors for proper connection, and correct as necessary. - - 2 Check the connector of M2 for proper drive coupling, and correct as necessary. - - 3 PS6 I/O check, sensor check JSCB PJ7JSCB-18 (ON) JS-504 F-3 4 M2 operation check JSCB PJ4JSCB-1 to 4 JS-504 F-6 5 Change M2 - - 6 JSCB F6 conduction check - - 7 Change JSCB.
When FS-527 is installed: 1 Check the motor and sensor connectors for proper connection, and correct as necessary. - - 2 Check the connector of M16 for proper drive coupling, and correct as necessary. - - 3 PS25 I/O check, sensor check FSCB PJ21-6 (ON) FS-527 J-3 4 M16 operation check FSCB PJ5-5 (REM) FS-527 B to C-9 5 Change M16 - - 6 Change FSCB
When FS-527 is installed: 1 Check the motor and sensor connectors for proper connection, and correct as necessary. - - 2 Check the connector of M16 for proper drive coupling, and correct as necessary. - - 3 PS25 I/O check, sensor check FSCB PJ21-6 (ON) FS-527 J-3 4 M16 operation check FSCB PJ5-5 (REM) FS-527 B to C-9 5 Change M16 - - 6 Change FSCB