Mã lỗi C1127 — Konica-Minolta bizhub C654

Code: C1127

Description: Punch oscillating motor’s drive malfunction
<When FS-535+PK-521 is installed> The PK punch home sensor (PS303) is not turned ON even after the set period of time has elapsed while the punch oscillating motor (M302) is energized.
Causes: • Punch oscillating motor (M302) • PK punch home sensor (PS303) • Punch control board (PKCB) • FS control board (FSCB)
Remedy: 1 Check the connector between M302-relay CN342- relay CN341-PKCB CN37 for proper connection, and correct as necessary. 2 Check the connector of M302 for proper drive coupling, and correct as necessary. 3 Check the connector between PS303-relay CN342- relay CN341-PKCB CN34 for proper connection, and correct as necessary. 4 PS303 I/O check, sensor check PKCB CN37-2 (ON) PK-521 5-C. 5 M302 operation check PKCB CN34-1 to 6 PK-521 5-C. 6 Replace M302. 7 Replace PKCB. 8 Replace FSCB.