Code: C2152
Description: Transfer belt pressure welding alienation
• At the completion of transfer belt pressure/retraction operations, the 1st transfer pressure sensor/K (PS51) is not in the status corresponding to each of the transfer belt pressure/retraction operations. See the table below. • Even after a predetermined period of time has elapsed since the transfer belt starts pressure/retraction operation, the 1st transfer pressure sensor/K (PS51) is not in the status corresponding to each of the transfer belt pressure/retraction operations. See the table below.
• At the completion of transfer belt pressure/retraction operations, the 1st transfer pressure sensor/K (PS51) is not in the status corresponding to each of the transfer belt pressure/retraction operations. See the table below. • Even after a predetermined period of time has elapsed since the transfer belt starts pressure/retraction operation, the 1st transfer pressure sensor/K (PS51) is not in the status corresponding to each of the transfer belt pressure/retraction operations. See the table below.
Causes: • 1st transfer pressure sensor/K (PS51) • 1st transfer pressure sensor/YMC (PS52) • 1st transfer pressure motor (M21) • Printer control board (PRCB)
Remedy: 1 Check the connector between M21-relay CN428- PRCB CN4 for proper connection and correct as necessary. 2 Check the connector of M21 for proper drive coupling and correct as necessary. 3 Check the transfer roller pressure gear of the transfer belt unit for proper engagement and the roller for rolling operation, and correct any faulty motion. 4 Check the connector between PS51-relay CN297- PRCB CN6 for proper connection and correct as necessary. 5 PS51 I/O check, sensor check PRCB CN6-1 (ON) 22-C. 6 M21 operation check PRCB CN4-5 to 8 3 to 4-K. 7 Replace M21. 8 Replace the transfer belt unit. 9 PRCB ICP5 or ICP24 conduction check. 10 Replace PRCB.