Mã lỗi C392A — Konica-Minolta bizhub C654

Code: C392A

Description: Heating roller temperature sensor contamination (Center of the heating roller)
While checking the contamination on the heating roller temperature sensor, detected temperature of the heating roller thermistor/1 exceeded the detected temperature of the heating roller temperature sensor for over the predetermined value for the predetermined period of time.
Causes: • Fusing unit • Heating roller temperature sensor (TEMS2) • Heating roller thermistor/1 (TH1) • IH power supply (IHPU) • DC power supply (DCPU) • Printer control board (PRCB)
Remedy: 1 Wipe the TEMS2 clean of dirt if any. <Cleaning procedure> • Clear away a dirt or a foreign object on the sensor with a cotton swab. • When a dirt is left even if you cleaned the sensor by above procedure, clear away a dirt or a foreign object on the sensor using a cotton swab dampened with the alcohol. And, wipe off the sensor with a dry cotton swab afterwards. 2 Check the TEMS2 for installed position and proper connector connection. - - 3 Check the TH1 for installed position and proper connector connection. - - 4 Check the connection of the fusing unit. 5 Check the fusing unit, IHPU, PRCB and DCPU for proper connection and correct or change as necessary. 6 Replace the fusing unit. 7 Replace PRCB.