Description: Paper output roller motor’s drive malfunction (When FS-535 is installed) The paper output roller home sensor (PS10) is not blocked or unblocked even after the set period of time has elapsed after the paper output roller motor (M6) is turned ON.
Causes: <When FS-535 is installed> • Paper output roller motor (M6) • Paper output roller home sensor (PS10) • FS control board (FSCB
Remedy: 1 Check the connector between M6-FSCB CN60 for proper connection and correct as necessary. 2 Check the connector of M6 for proper drive coupling, and correct as necessary. 3 Check the connector between PS10-relay CN211- FSCB CN21 for proper connection and correct as necessary. 4 PS10 I/O check, sensor check FSCB CN21-3 (ON) FS-535 6-L. 5 M6 operation check FSCB CN60-9 to 12 FS-535 16-D. 6 Replace M6. 7 FSCB ICP19 conduction check. 8 Replace FSCB.