Description: Tri-fold guide motor’s malfunction <When FS-535+SD-512 is installed> The tri-fold guide home sensor (PS7) is not not blocked or unblocked even after the set period of time has elapsed after the tri-fold guide motor (M6) is turned ON.
Causes: <When FS-535+SD-512 is installed> • Tri-fold guide motor (M6) • Tri-fold guide home sensor (PS7) • SD drive board (SDDB) • FS control board (FSCB)
Remedy: 1 Check the connector between M6-SDDB J9 for proper connection, and correct as necessary. 2 Check the connector of M6 for proper drive coupling, and correct as necessary. 3 Check the connector between PS7-SDDB J9 for proper connection, and correct as necessary. 4 PS7 I/O check, sensor check SDDB J9-6 (ON) SD-512 4-G. 5 M6 operation check SDDB J9-7 to 10 SD-512 3-F to G. 6 Replace M6. 7 Replace SDDB. 8 Replace FSCB.