Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi C3925 — Konica-Minolta bizhub C654e

Code: C3925

Description: Fusing sensor wire breaks detection (Main of the heating roller)
After a predetermined period of time after the warm-up stage is started, the heating roller temperature sensor voltage does not increase by predetermined steps (temperature rise) within a predetermined period of time.
Causes: • Fusing unit • Heating roller temperature sensor (TEMS2) • IH power supply (IHPU) • Noise filter (NF1) • Printer control board (PRCB)
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the open/close operation of the upper right door. 3 Check the fusing unit, IHPU, NF1 and PRCB for proper connection and correct or change as necessary. 4 Replace the fusing unit. 5 Replace IHPU. 6 Replace PRCB. 7 Replace NF1.